<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-23 04-29-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
99.60 MHz 5/5, 67 dBuV Classic
Pilot RDS Phase Difference
6.9 kHz 2.9 kHz 85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 63 kHz 19019 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,2 dBr 1,51 dBr 3,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"Classic " 62A1 13 (Light M) 1 0 1 1 --:--
RT
"Bbc Philharmonic Orchestra "
AF EON
94.8, 96.2, 99.6, 107.4 MHz -
FM Scope Max at: 63 kHz MIN: 10 kHz % above 76 kHz: 0,0000 Acquired: 2024/10/23 4.28.19 Total samples: 19019 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 3,6 dBr MIN: -1,2 dBr AVE: 1,51 dBr % above 12,2 dBr: 0,0 Last value: 3,3 dBr (2024/10/23 4.28.19) 04.14 04.16 04.18 04.20 04.22 04.24 04.26 04.28 0 50 100 Dev. MAX [kHz] -2 0 2 4 Pm [dBr]